Overview

Dashboard

SCSWIN - Environment Overview

This is a comprehensive view of your entire SCS Win environment. Here you can see every location connected and by clicking on your chosen location you can see it's selected alerts and objects. Through this dashboard with object viewer you can also see do preliminary analytics with Object List, Metric Picker and Metric Chart.

SCSWIN - Environment Overview Dashboard

Custom Groups

The 'Facility Safety with SCS-Win' addon provides custom groups to help organize and manage various facility safety and infrastructure components within Aria Operations.

Custom Group NameDescription
SCSWin WorldContains all objects related to the SCSWin system, including controllers, power systems, locations, and more.

Collected objects

Relationships

Diagram illustrating the connections between objects, referred to as relationships.

Relations between collected objects

The relationship diagram illustrates a hierarchy that begins with the 'SCS Win Adapter Instance', which serves as the core component responsible for integrating data from the SCS Win system. The hierarchy then follows this structure:

  • 'SCS Win Adapter Instance' connects to 'SCS Win Location' representing Locations in which components are monitored
  • 'SCS Win Location' connects to 'SCS Win Controller' which controles colection of data from all devices in system
  • From 'SCS Win Controller' other objects branchout out as they collect their respective data

SCS Win Location

Represents a location in the SCS Win system, uniquely identified by its name.

Data NameTypeDescription
NazwaPropertyThe unique name of the Location

SCS Win Controller

Represents a controller in the SCS Win system, identified by a unique ID and name.

Data NameTypeDescription
IDPropertyThe unique ID of the Controller
NazwaPropertyThe unique name of the Controller
LokalizacjaPropertyThe name of localization to which controller belongs
IPPropertyThe Controller's IP address

SCSWin Air Conditioner

Represents an air conditioner unit in the SCS Win system, identified by a unique ID and name.

Data NameTypeDescription
IDPropertyThe unique ID of the Air Conditioner
NazwaPropertyThe unique name of the Air Conditioner
LokalizacjaPropertyThe name of localization to which Air Conditioner belongs
IPPropertyThe Air Conditioner's IP address
ID sterownikaPropertyThe ID number of controller to which Air Conditioner belongs
PressureInstanced MetricReading pressure from all detectors. Unit: bar
TemperatureInstanced MetricReading temperature from all detectors. Unit: C
FrequencyInstanced MetricReading frequency levels from all detectors. Unit: Hz
PowerInstanced MetricReading power levels from all detectors. Unit: W
CapacityInstanced MetricReading capacity levels from all detectors. Unit: Ah
PercentageInstanced MetricDisplaying data in form of percentage. Unit: %
VoltageInstanced MetricReading Voltage levels from all detectors. Unit: V
CurrentInstanced MetricReading Current levels from all detectors. Unit: A
TimeInstanced MetricDisplays time. Unit: seconds, minutes, hours

SCSWin Access Control

Represents an access control device in the SCS Win system, identified by a unique ID and name.

Data NameTypeDescription
IDPropertyThe unique ID of the Access Control
NazwaPropertyThe unique name of the Access Control
LokalizacjaPropertyThe name of localization to which Access Control belongs
IPPropertyThe Access Control's IP address
ID sterownikaPropertyThe ID number of controller to which Access Control belongs

SCSWin Controller ZSN

Represents a ZSN controller in the SCS Win system, identified by a unique ID and name.

Data NameTypeDescription
IDPropertyThe unique ID of the ZSN Controller
NazwaPropertyThe unique name of the ZSN Controller
LokalizacjaPropertyThe name of localization to which ZSN Controller belongs
IPPropertyThe ZSN Controller's IP address
ID sterownikaPropertyThe ID number of controller to which ZSN Controller belongs

SCSWin Room

Represents a room in the SCS Win system, identified by a unique ID and name.

Data NameTypeDescription
IDPropertyThe unique ID of the Room
NazwaPropertyThe unique name of the Room
LokalizacjaPropertyThe name of localization to which Room belongs
IPPropertyThe Room's IP address
ID sterownikaPropertyThe ID number of controller to which Room belongs
TemperatureInstanced MetricReading temperature from all detectors. Unit: C
PercentageInstanced MetricDisplaying data in form of percentage. Unit: %

SCSWin Power Supply System

Represents a power supply system in the SCS Win system, identified by a unique ID and name.

Data NameTypeDescription
IDPropertyThe unique ID of the Power Supply System
NazwaPropertyThe unique name of the Power Supply System
LokalizacjaPropertyThe name of localization to which Power Supply System belongs
IPPropertyThe Power Supply System's IP address
ID sterownikaPropertyThe ID number of controller to which Power Supply System belongs
TemperatureInstanced MetricReading temperature from all detectors. Unit: C
VoltageInstanced MetricReading Voltage levels from all detectors. Unit: V
Electric CurrentInstanced MetricReading Current levels from all detectors. Unit: A

SCSWin Telecom Power Supply System

Represents a telecom power supply system in the SCS Win system, identified by a unique ID and name.

Data NameTypeDescription
IDPropertyThe unique ID of the Telecom Power Supply System
NazwaPropertyThe unique name of the Telecom Power Supply System
LokalizacjaPropertyThe name of localization to which Telecom Power Supply System belongs
IPPropertyThe Telecom Power Supply System's IP address
ID sterownikaPropertyThe ID number of controller to which Telecom Power Supply System belongs
CapacityInstanced MetricReading capacity levels from all detectors. Unit: Ah
VoltageInstanced MetricReading Voltage levels from all detectors. Unit: V
TimeInstanced MetricDisplays time. Unit: seconds, minutes, hours

SCSWin Rack

Represents a rack in the SCS Win system, identified by a unique ID and name.

Data NameTypeDescription
IDPropertyThe unique ID of the Rack
NazwaPropertyThe unique name of the Rack
LokalizacjaPropertyThe name of localization to which Rack belongs
IPPropertyThe Rack's IP address
ID sterownikaPropertyThe ID number of controller to which Rack belongs

SCSWin UPS

Represents an uninterruptible power supply (UPS) in the SCS Win system, identified by a unique ID and name.

Data NameTypeDescription
IDPropertyThe unique ID of the Air Conditioner
NazwaPropertyThe unique name of the Air Conditioner
LokalizacjaPropertyThe name of localization to which Air Conditioner belongs
IPPropertyThe Air Conditioner's IP address
ID sterownikaPropertyThe ID number of controller to which Air Conditioner belongs

SCSWin Unknown (objects that do not have a 'Typ_obiektu' specified)

Represents an unknown object in the SCS Win system, identified by a unique ID and name.

Data NameTypeDescription
IDPropertyThe unique ID of an unknown object
NazwaPropertyThe unique name of an unknown object
LokalizacjaPropertyThe name of localization to which an unknown object belongs
IPPropertyThe unknown object's IP address
ID sterownikaPropertyThe ID number of controller to which an unknown object belongs
PressureInstanced MetricReading pressure from all detectors. Unit: bar
TemperatureInstanced MetricReading temperature from all detectors. Unit: C
FrequencyInstanced MetricReading frequency levels from all detectors. Unit: Hz
PowerInstanced MetricReading power levels from all detectors. Unit: W
CapacityInstanced MetricReading capacity levels from all detectors. Unit: Ah
PercentageInstanced MetricDisplaying data in form of percentage. Unit: %
VoltageInstanced MetricReading Voltage levels from all detectors. Unit: V
CurrentInstanced MetricReading Current levels from all detectors. Unit: A
TimeInstanced MetricDisplays time. Unit: seconds, minutes, hours

Alerts

Alerts are defined in your SCS Win Environment. They will carry alarm priority to Aria Operations based on values in below table

Win SCS alarm priorityArOps criticality
0 (urgent) and 5 (critical)critical
1 (non-urgent) and 2 (info)info
3 (power loss)warning